CODAN VSAT high power series of outdoor mounting VSAT C Band and VSAT Ku Band SSPAs offer a wide range of distinctive advantages and enhanced features for satellite and communications systems based in remote or challenging geographic regions.
Key features
Output power
The VSAT C-Band CODAN SSPA offer an output power rating of either 60 or 120 watts while the VSAT Ku-Band CODAN SSPA is rated at 40 watts.
Durability
The CODAN VSAT SSPAs are designed and tested to meet their performance specifications in an ambient temperature range from -40°C to +55°C and up to 100% relative humidity, ensuring long-term survival in extreme conditions. Field experience indicates that MTBFs of greater than 60,000 hours can be expected.
RF performance
RF performance is superb, particularly: intermodulation performance, gain stability over temperature and flatness across the RF band.
The CODAN VSAT SSPAs also boast industry leading spurious and harmonics specifications, while guaranteed RF performance ensures expensive system link margins do not have to be used to cope with CODAN VSAT SSPA RF performance variations. The high linearity and low spurious characteristics contribute to superior multi-carrier performance.
Power consumption
CODAN high power VSAT SSPAs feature low power consumption and low temperature rise, ensuring internal components do not suffer undue stress.
Power supply
All the high power SSPAs are AC mains powered and automatically operate from either 115 V AC or 230 V AC.
Internal protection
Internal protection against high temperature and short or open circuit RF output is standard.
Advanced features
Local control
The user-friendly, PC-based SSPA Manager software is provided for operator control and monitoring of the SSPA. The operating configuration is stored in the SSPA EEPROM to ensure the setup parameters are restored in the event of a power failure.
Enhanced monitor and control
All operating functions can also be controlled and monitored via the serial M&C interface. Functions that can be monitored include RF output power, heatsink temperature and internal supply rail voltages. The serial interface can also be used to perform a self test, mute the SSPA, and set the gain and maximum/minimum RF power alarm thresholds.
The SSPA is supplied with RS232, RS422 and RS485 interfaces.
CODAN VSAT Redundancy switching system
CODAN VSAT redundancy switching system can provide automatic changeover to a second SSPA, maximising availability and minimising any disruption to service.
The CODAN VSAT redundancy switching system is fully outdoor mounted, but can be supplied with an indoor rack mounted SSPA Redundancy Monitor to provide indoor monitor and control of the redundant SSPA system.
Major configuration options
Frequency bands
VSAT C-Band
5.850 - 6.425 GHz
VSAT Ku-Band
14.0 - 14.5 GHz
Output powers (VSAT C-Band)
CODAN 5760
60W
CODAN 5712Н
120W
WR137 waveguide output standard.
Output power (VSAT Ku-Band)
CODAN 5940
40W
WR75 waveguide output standard.
M&C serial interface
RS232
Standard
RS422
Standard
RS485
Standard
Options and accessories
Antenna pole mounting kit
CODAN 5588
SSPA Redundancy Controller (outdoor mounting).
CODAN 5589
SSPA Redundancy Monitor (indoor rack mounting, includes 50 m interconnecting cable).
CODAN quality and service
The SSPAs are built and tested in CODAN ISO9001 quality certified manufacturing facility, and undergo 100% burn in and performance testing.
CODAN fully trained staff and agents provide in-factory and in-country training services, and complete installation and on-site assistance. This service is backed up by a 24 hour customer service line and a warranty of three years on manufacturing, design or component defects.
Technical specifications of VSAT C-Band SSPA CODAN 5760/5712H
Frequency range
Frequency range
5.850 to 6.425 GHz
Output power @ 1 dB GCP
CODAN 5760
+47.8 dBm (60W) typical
+47.0 dBm (50W) minimum
CODAN 5712H
+50.8 dBm (120W) typical
+50.0 dBm (100W) minimum
Third order intermodulation products
(2 equal carriers each @ 6 dB OPBO from 1 dB GCP)
-26 dBc maximum
Gain
Gain @ rated output power
65 dB minimum (0 dB SSPA attenuator setting)
Gain variation
5.850 to 6.425 GHz
В любой полосе 40 МГц
+1.0 dB maximum +0.3 дБ максимум
Gain stability
+1.5 dB maximum, -40°C to +55°C
Gain adjustment
0 dB to -20 dB in 0.2 dB steps
Noise power
(@ max gain)
-90 dBm/Hz maximum
AM/PM conversion
(@ 1 dB OPBO from 1 dB GCP)
2°/dB maximum
Spurious output
(@ rated output power, in band)
-65 dBc maximum
Harmonics
(@ rated output power)
-50 dBc maximum
Group delay (over 40MHz)
Linear
0.03 ns/MHz
Parabolic
0.003 ns/MHz2
Ripple
1 ns p-p
VSWR
Input
1.3:1 maximum
Output
1.25:1 maximum
Protection
Over temperature shutdown
Output isolator
Monitor and control
Monitor
RF power meter
RF monitor @ -41 dBc nominal
FET flange temperature
Internal supply rail voltages
Status and alarms
Control
Mute
Gain
High/low power thresholds
Summary alarm
Over temperature
FET failure
Low/high RF power
Alarm logic levels
Dry relay contacts
Serial interface
RS232/RS422/RS485
Data rate
300/1200/2400/9600 bit/s
DC outputs
Main output
-48 V DC
Auxiliary output
-48 V DC
Total capacity
75W (1.5 A) maximum
Connectors
RF input
N female, 50 Om
RF output
CPR137G flange (8 holes, M5 x 8mm deep)
RF monitor
N female, 50 Om
Monitor and control
MS3114E14-19P
AC input
Amphenol T3110 000
-48 V DC outputs
MS3114E8-2S
Power supply
Voltage
104 to 274 V AC, 47 to 63 Hz
Consumption
CODAN 5760
CODAN 5712Н
460 VA typical
740 VA typical
Operating environment
Operating temperature range
-40°C to +55°C
Relative humidity
100%
Sealing
IP66
Cooling
Forced air
Mechanical
Size
280mm W x 355mm D x 495mm H
Weight
27 kg
Technical specifications of VSAT Ku-Band SSPA CODAN 5940
Frequency range
Frequency range
14.0 to 14.5 GHz
Output power @ 1 dB GCP
Output power @ 1 dB GCP
+46.7 dBm (47W) typical
+46.0 dBm (40W) minimum
Third order intermodulation products
(2 equal carriers each @ 6 dB OPBO from 1 dB GCP)
-25 dBc maximum
Gain
Gain @ rated output power
60 dB minimum (0 dB SSPA attenuator setting)
Gain variation
14.0 to 14.5 GHz
Any 40MHz band
+1.0 дБ максимум +0.3 dB maximum
Gain stability
+1.5 dB maximum, -40°C to +55°C
Gain adjustment
0 dB to -20 dB in 0.2 dB steps
Noise power
(@ max gain)
-82 dBm/Hz maximum
AM/PM conversion
(@ 1 dB OPBO from 1 dB GCP)
2°/dB maximum
Spurious output
(@ rated output power, in band)
-65 dBc maximum
Harmonics
(@ rated output power)
-50 dBc maximum
Group delay (over 40MHz)
Linear
0.03 ns/MHz
Parabolic
0.003 ns/MHz2
Ripple
1 ns p-p
Return loss
Input
1.3:1 maximum
Output
1.25:1 maximum
Protection
Over temperature shutdown
Output isolator
Monitor and control
Monitor
RF power meter
RF monitor @ -40 dBc nominal
FET flange temperature
Internal supply rail voltages
Status and alarms